Commissioning
Code Possible Settings
IMPORTANT
No. Name Default Selection
NOTE
When input is activated, settings 1...7 override P101
When TB-13A...TB-13D are configured for Auto References other than MOP, TB-13D overrides TB-13C, TB-13C overrides
TB-13B and TB-13B overrides TB-13A. Any other Auto Reference will have priority over MOP.
Settings 10...14 are only valid in Terminal Strip mode (P100 = 1, 4, 5, 6)
If Start/Run/Jog Forward and Start/Run/Jog Reverse are both activated, drive will STOP
If Jog input is activated while drive is running, the drive will enter Jog mode; when Jog input is deactivated, drive will STOP
An
fault will occur if the Assertion Level switch (ALsw) position does not match the P120 setting and any of the digital
inputs (P121...P124) are set to a value other than 0.
An I fault will occur under the following conditions:
- TB-13A...TB-13D settings are duplicated (each setting, except 0, 3 and 23, can only be used once)
- One input is set to “MOP Up” and another is not set to “MOP Down”, or vice-versa.
- One input is set to 10 and another input is set to 11…14.
- One input is set to 11 or 12 and another input is set for 13 or 14.
Typical control circuits are shown below:
- If any input is set to 10, 12 or 14, P112 must be set to 1 for Reverse action to function.
Run / Stop
with Direction
P121 = 10
Start Forward /
Start Reverse
P121 = 11, P122 = 12
Run Forward /
Run Reverse
P121 = 13, P122 = 14
1 4
13A
FWD
REV
STOP
RUN
1 4
13A 13B
RUN
REV
RUN
FWD
FWD
REVSTOP
1 4
13A 13B
Acceleration Time 2 20.0 0.0 {s} 3600 Selected using TB-13A...TB-13D (P121...
P124 = 17)
For S-ramp accel/decel, adjust P106
P 26
Deceleration Time 2 20.0 0.0 {s} 3600
7
Deceleration Time
for Auxiliary Ramp
to Stop
20.0 0.0 {s} 3600 Selected using TB-13A...TB-13D (P121...
P124 = 19).
For S-ramp accel/decel, adjust P106
Once executed, this ramp time has priority over
P105 and P126.
Automatic Accel/
Decel rate switch
threshold
0.0 0.0 {Hz} 1000 If Actual Frequency < P129 Use Accel/decel time
#2 (P125/P126)
If Actual Frequency > P129 Use Accel/decel time
#1 (P104/P105)
Preset Speed #1 0.0 0.0 {Hz} 500
PRESET
SPEED
13A 13B 13C 13D
1 X -- -- --
2 -- X -- --
3 -- -- X --
4 X X -- --
4 (alternate) -- -- -- X
5 X -- X --
6 -- X X --
7 X X X --
8 (alternate) -- X -- X
8 (alternate -- -- X X
Speed setting is used by P158
13D available on 15HP (11kW) & higher drives.
Preset Speed #2 0.0 0.0 {Hz} 500
Preset Speed #3 0.0 0.0 {Hz} 500
Preset Speed #4 0.0 0.0 {Hz} 500
Preset Speed #5 0.0 0.0 {Hz} 500
Preset Speed #6 0.0 0.0 {Hz} 500
7
Preset Speed #7 0.0 0.0 {Hz} 500
Preset Speed #8 0.0 0.0 {Hz} 500