Overview
18 313528E
Soft Key
Soft keys activate the mode or action represented by the icon above each button in the LCD.
See Table 6 for soft key modes and actions.
Table 5: Display Module Button Functions
Key Function
Table 6: Display Soft Key Icons
Icon Function
Depressurize Depressurize relieves fluid pressure from the pump outlet to below the platen on the currently
active ram.
If system is pressurized, press button.
When prompted to depressurize the system, select or . Depressurizing the
active ram will depressurize both rams.
NOTE: If additional user-supplied check valves have been added to the system, only the active
ram will be depressurized. You must perform manual crossover and select depressurize again
to depressurize both rams. See Crossover section of this table on page 19.
If system is depressurized, press button.
When prompted to pressurize the system, select or .
Pump Prime
Pump Prime
Tandem ram: if pump is off, activates the air solenoid on the active ram;
Tandem ram: if pump is on, activates the air solenoid on the inactive ram which enables you
to purge air and prime the pump;
Single ram: activates air solenoid whether or not pump is on;
clears the Pump Not Primed deviation or alarm (depending on setup selection); and
resets the drum volume remaining to the drum fill volume setpoint for pump being primed.
Press button.
When prompted to prime the ram, select to prime.
Press button to exit Prime Mode or to reset counter to the prime time.
When prompted to exit Prime Mode, select to exit or to reset prime counter.
Recirculate Recirculate Mode pumps fluid from the drum, through the pump, and back into the drum on the
currently active ram.
Set motor air regulator to 30 psi (0.2 MPa, 2.1 bar) before pressing Recirculate key.
If system is not in Recirculate Mode, press button.
When prompted to turn recirculation on, select or . Adjust motor air regulator to
obtain desired flow rate.
If system is in Recirculate Mode, press button.
When prompted to turn recirculation off, select or .