Graco 313528E Bedienungsanleitung Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 46
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
Overview
16 313528E
255468 Light Tower Accessory
Order the 255468 Light Tower Accessory as a diagnos-
tic indicator for tandem supply systems. Refer to Light
Tower Kit manual for installation instructions. See Table
4 for a description of light tower signals.
Communications Gateway
Module
The Communications Gateway Module (CGM) provides
a control link between Graco Control Architecture based
systems and a selected fieldbus. This provides the
means for remote monitoring and control by external
automation systems.
Data provided by the CGM to the fieldbus depends on
which Graco Control Architecture based system and
fieldbus are connected. A data map supplied on a map
token is defined for this pairing. Once the data map has
been loaded into the CGM, it is stored internally, and the
map token is no longer required for operation.
CGM Status LED Signals
*The red LED (F) will flash a code, pause, then repeat.
See for diagnostic information in CGM manual 312864.
NOTE: Verify that you are using the correct token for
your system and reinstall token. If fails, order new
token.
Table 4: Light Tower Signals
Signal Description
Green on only System is powered up and there
are no error conditions present.
Yellow flashing A low priority error exists.
Yellow on A medium priority error exists.
Red flashing A high priority error exists.
Red on The system is shut down due to
error conditions.
Signal Description
Green on System is powered up
Yellow Internal communication in progress
Red
Solid
CGM hardware failure
*Red
(7 flashes)
Data map load failure
Incorrect data map for fieldbus type
No data map loaded