Seitenansicht 11
Overview
12 313528E
Pneumatic Crossover System Components
NOTE:
D200, D60, and S20 sizes are used in pneumatic
crossover systems.
F
IG. 2. shows a pneumatic crossover system. Refer to
manual 313526 (supplied) for ram installation and oper-
ating instructions. The pneumatic crossover operates as
follows:
During system operation, as the ram approaches the
drum bottom, the top of the ram contacts the limit switch
(E). The limit switch shuts off air to the air motor via a
solenoid valve (Y), which stops air flow to one motor and
starts air flow to the other air motor. This allows continu-
ous material flow and changing of material drums.
The position of the limit switch (E) on the ram deter-
mines when the air motor is turned off. Start by position-
ing the limit switch to trip when the ram platen (D) is 1 in.
(25 mm) from the bottom of the drum. During operation
the position may be adjusted as desired.
The bypass valve (L) allows you to prime the inactive
pump after a drum change. Open the valve to prime the
pump. Close the valve when priming is complete, and
during normal operation.