Installation
22 313296J
Heater Resistance Checks
NOTE: For dispense valve and hose sensor resis-
tance checks, refer to your dispense valve manual
or hose manual.
To check heater resistance:
1. Make sure the power is off and that the disconnect
switch is in the OFF position.
2. Make electrical resistance checks for the compo-
nents. Refer to Table 7. Heater terminal pins are
located on the back of the enclosure (H). See F
IG
. 2,
page 8.
3. Replace any parts whose resistance readings do
not comply with the ranges listed in Table 7.
NOTE: Check resistance at ambient room tempera-
ture (63°– 77°F [17°– 25°C]
).
Conduct these electrical checks with the main power
disconnect OFF.
Table 7: Resistance Chart of All Heaters
Zone Component
Between
Terminals
Unit
Voltage
Range
(ohms)
1 Platen - D200 1 and 3 240 15 +5/-5
2 Platen - D60 1 and 3 240 80 +10/-10
3 Pump L and N 240 37 +5/-5
F
IG
. 15: Heater Terminal Pins
1
L
N
3
Seitenansicht 21