L12100
6
1. HANDLE
2. PISTON
3. DETENT BALL
4. RELIEF-TO-TANK
PORT
5. CONNECTING PORT
6. CHECK VALVE
7. OUTLET
8. LUBE CAVITY
9. BALL DETENT CAVITY
10. GAUGE PORT
7
10
2
3
4
5
9
8
A
A
VIEW “A-A
FRONT
VIEW
1
FEATURES / BENEFITS
Interchangeable reservoirs make it easy to customize the
pump package for each application.
Simple, positive-displacement pump design keeps the number
of wear parts to a minimum for extended pump life.
Built-in bleed mechanism provides system pressure venting
when the pump handle is returned to the fully upright
position.
3000 psi pressure gauge provides a fast check on system
status.
OPERATION
Figure 6 shows a cutaway view of a hand-operated pump. As the
pump handle (1) is pulled down, piston (2) moves forward past the
detent (3) closing the relief to tank port (4). Further forward motion
of piston (2) displaces the volume of lubricant in cavity (8) through
connecting port (5) and check valve (6) and to the outlet (7). The
handle is then partially returned until the detent ball (3) contacts,
but does not retract into, the ball indent cavity. If the handle is
returned too far, the pressure built up in the lube cavity (8) will be
vented, indicated by a decrease in the pressure gauge’s reading.
Continue to stroke the pump until the pressure gauge reads 1500
psi (103 bar) for oil or 2500 psi (173 bar) for grease). After system
pressure has been attained, causing all the injectors to dispense
lubricant, the pump handle is returned to the full upright position
(past the detent). This allows system pressure to vent through port
(4) back to reservoir, thereby allowing the injectors to reset and
prime for their next delivery of lubricant.
PRESSURE GAUGES
Pressure Gauges are installed in the pump outlet to allow the
operator to know when correct pressure has been attained.
When correct pressure has been reached, the operator returns
the handle to the full upright position, venting line pressure and
allowing the injectors to reset.
Figure 6. Hand-Operated Pump - Operation
(Full upright position shown)
Page 10
SPECIFICATION
Pump Body Material Aluminum and steel
Pump Output 0.125 cu.in (2.0 cm
3
) per stroke
Max Operating Pressure 3000 psi (207 bar)
Force to Operate Handle 20 lbs (9 kg) per 1000 psi (69 bar)
Lubricant Oil or Grease (NLGI #1 or lighter)
Reservoir Capacities
(for oil or grease, plastic)
6 pints (2.84 liters) or 6 lbs (2.72 kg)*
12 pints (5.68 liters) or 12 lbs (5.44 kg)*
20 pints (9.46 liters) or 20 lbs (9.06 kg)*
*Nominal grease reservoir size is based on a direct conversion of oil
reservoir capacity and does not refl ect volume loss due to the follower
and spring. Actual volumes containd are: 6 lb (2.6 lb), 12 lb (5.8 lb), 20
lb (11.8 lb).