Instructions, Repair and PartsDyna-Star® HP Pump System332540EProvides lubricant flow and pressure to operate a single line parallel automatic lubrica
Parts List 10 332540EParts ListModel 77X100: Dyna-Star Pump, 60#, Dip Stick, Reservoir, Cover, Vent ValveModel 77X101: Dyna-Star Pump, 90#, Dip Stick,
Parts List332540E 11Parts ListModel 77X102: Dyna-Star Pump, 60#, Auto-Fill Shut Off, Reservoir, Cover, Vent ValveModel 77X103: Dyna-Star Pump, 90#, Au
Parts List 12 332540EParts List Replacement Danger and Warning labels, tags and cards are available at no cost.Cable Harness Kits (all models)Ref. No
Technical Data332540E 13Technical DataMaximum working pressure 3500 psi (24.1 MPa, 241 barPump wetted parts See Dyna-Star HP and HF Pump manual: 33251
Dimensions 14 332540EDimensionsRef 60 lb Models 90 lb ModelsUS (inch) Metric (cm) US (inch) Metric (cm)A 30.5 77.47 38.0 96.52B 14.5 36.83 14.5 36.83
Notes332540E 15Notes
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th
Warnings 2 332540EWarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point
Warnings332540E 3PRESSURIZED EQUIPMENT HAZARDOver-pressurization can result in equipment rupture and serious injury.• A pressure relief valve is requi
Warnings 4 332540EBURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns:• Do not touch ho
Typical Installation: Injector System332540E 5Typical Installation: Injector SystemThe installation shown in below is only a guide for selecting and i
Typical Installation: Series Progressive System 6 332540ETypical Installation: Series Progressive System The installation shown below is only a guide
Installation332540E 7InstallationPressure ReliefFollow the Pressure Relief Procedure whenever you see this symbol.To relieve pressure in the system, u
Operation 8 332540EReservoir Installation1. Mount Reservoir on sturdy, flat surface. Note loca-tion of Fill Port (G) and Lubricant Outlet Connection (
Operation332540E 9Filling ReservoirThere are two reservoir filling options; Fill Port (G) or Auto-Fill Shut Off (S). Only one method of filling can be