DESCRIPTION OF OPERATION
POSITIVE DISPLACEMENT SEQUENTIAL FUNCTION
The normal "ready" state of the system is as follows:
The dispense valve may operate with a (remote) reservoir or with a syringe (mounted with the valve).
In the ready state, the syringe or reservoir contains dispensable material. The system has been
purged, filling the Dispense Tube and needle with material. The Bottom Pinch-Off Piston is not
pressurized (forward) but is held back by the springs, closing the Dispense Tube and holding back the
dispensable material. (See "Fill" on drawing below.) The Top Pinch-Off and Dispense Pistons are not
pressurized (back).
The dispense cycle begins when the controller is activated.
The Top Pinch-Off Piston first moves forward to stop material supply and the Bottom Pinch-Off Piston
moves forward to release the Dispense Tube. (See "Dispense Delay" on Sequential Function drawing.)
The Dispense Piston then moves forward until stopped by the Micrometer Stroke Adjust. This
squeezes a precise amount of material out of the Dispense Tube. (See "Dispense" on Sequential
Function drawing.)
When the dispense cycle is complete, the spring pushes the Bottom Pinch-Off Piston back, sealing the
Dispense Tube to prevent material drip. Immediately after, the Dispense Piston and Top Pinch-Off
Piston withdraw allowing the material from the pressurized reservoir to refill the Dispense Tube. The
system is again, in the normal "ready" state.