INSTRUCTIONS-PARTS LIST
■mmucnoNt
This manual contains important
warnings and information.
READ AND RETAIN FOR REFERENCE
<3
ORACO
307-947
Rev. E
Supersedes D
Model AA2000
High Efficiency Low Pressure"” System
Air-Assisted Airiess Spray Gun
Part Number 222-615, Series C
950 psi (66 bar) Maximum Working Fluid Pressure
100 psi (7 bar) Maximum Working Air Pressure*
10 psi (0.7 bar) Maximum Operating Air Pressure**
* The Maximum Working Air Pressure indicates the maxi
mum air pressure the gun was designed to operate safely
under.
** The Maximum Operating Air Pressure indicates the maxi
mum air pressure the air cap supplied with this gun was
designed to operate at or below to comply with California
Wood Rule 1136. To guarantee compliance to rule 1136,
the gun must be used with Air Regulator Part No. 110-776.
This regulator limits the operating pressure to 10 psi (0.7
bar), using an air supply pressure of 100 psi (7 bar).
U.S. Patent Nos. 3,843,052; 4,386,739
United Kingdom Patent No. 2 111 406 B
Patented 1984 Canada
Brevete 1984
French Patent No. 82-21202
Foreign Patents Pending
GRACO INC.
P.O. BOX 1441 MINNEAPOLIS, MN
©COPYRIGHT 1988, GRACO INC.
55440-1441
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - INSTRUCTIONS-PARTS LIST

INSTRUCTIONS-PARTS LIST mmucnoNtThis manual contains important warnings and information.READ AND RETAIN FOR REFERENCE<3ORACO307-947Rev. E Supersede

Seite 2 - Table of Contents

OperationFlush the Gun DailyWARNINGPressure Relief ProcedureTo reduce the risk of serious injury, including fluid injection, splashing in the eyes or

Seite 3 - WARNINGS

TroubleshootingWARNINGTo reduce the risk of serious injury, including fluid injection, splashing fluid or solvent in the eyes or on the skin, or injur

Seite 4 - HOSE SAFETY

Service WARNINGTo reduce the risk of serious injury, including fluid injection, and splashing in the eyes or on the skin, or injury from moving parts

Seite 5 - IMPORTANT

ServiceA A— DETAIL D —Fluid Needle Packings (47)A. AAAAAAAAAAAA A 30SERVICE NOTES:Gasket (33) must be replaced if fluid connector (67 or 1-see page 1

Seite 6 - Installation

PartsA 33'For Direct Hose Connection(Paris shipped unassembled)SERVICE NOTES (See Fig. 7 for additional Information):A Gasket (33) must be replac

Seite 7

PartsUse Only Genuine Greco Parts and Accessories.Ref.No.Part No. DescriptionQty.1178-415 CONNECTOR, fluid (not assembled)12106-917ADAPTER, air13178-4

Seite 8

AccessoriesUse Only Genuine Grace Parts and AccessoriesFluid Filters3000 psi (207 bar) Maximum Working Pressure 214-570 with carbon steel bowl and sup

Seite 9

AccessoriesUse Only Genuine Grace Parts and AccessoriesAir Pressure Verification Kit 224-250For use in checking air cap pressure at various gun inlet

Seite 10 - Operation

Spray Tip SelectionSTANDARD SPRAY TIPSOrificeSize(Inches)Inches Fan Width at 12” (300 mm)‘Light to Medium Viscosity fl oz/mln (llters/mln)‘Heavy Vis

Seite 11 - Troubleshooting

Technical DataDimensionsMaximum Working Fluid Pressure ... 950 psi (66 bar)*Maximum Working Air Pressure...100 psi (7 bar)**Maximum Oper

Seite 12 - 307-947

Table of ContentsSafety Warnings... 3InstallationVentilate the Spray Booth...

Seite 13 - 307-947 13

The Grace Warranty and DisclaimersWARRANTYGraco warrants all equipment manufactured by it and bearing its name to be free from defects in material and

Seite 14 - A Lubricate threads

WARNINGSHigh Pressure Spray Can Cause Serious Injury. For Professional Use Only.Observe All Warnings. Read and understand all instruction manuals befo

Seite 15 - Optional Parts

FIRE OR EXPLOSION HAZARDstatic electricity is created by the flow of fluid through the pump and hose. If every part of the equipment is not properly g

Seite 16 - Accessories

EQUIPMENT MISUSE HAZARDGeneral SafetyAny misuse of the equipment or accessories, such as overpressurizing, modifying parts, using incompatible chemica

Seite 17

InstallationKEYAGun Air InletGPump Ground WireBGun Fluid InletHAir Line FiltercBleed-Type MasterJFluid Drain VaiveAir VaiveKGun Air HoseDMain Air Supp

Seite 18 - Spray Tip Selection

Connect the Air LineInstall an air line filter (H) to ensure a clean, dry air supply to the gun. Dirt and moisture in the line can ruin the appear

Seite 19 - Change Summary

OperationSelect a Spray TipUse the Spray Tip Selection charts on page 18, as a guide tor selecting an appropriate spray tip tor your application. The

Seite 20 - Graco Phone Numbers

OperationAdjust the Spray Pattern & Apply the Fluid (Continued)Increase the fluid pressure just to the point where a further increase in fluid pre