ENG
Operation - Maintenance
PD44
Metering Valves and Feed Systems
Meter, mix, and dispense system for precise two-component micro-dispensing of sealants
and adhesives.
Not approved for use in European explosive atmosphere locations.
See page 3 for model information, including maximum
working pressure and approvals. See page 6 for prod-
uct configuration information.
Important Safety Instructions
Read all warnings and instructions in this man-
ual. Save these instructions.
Linear Resistive Transducer PD44 Meter-
ing Valve shown, Feed Systems not shown
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Operation - Maintenance

313876FENGOperation - MaintenancePD44Metering Valves and Feed SystemsMeter, mix, and dispense system for precise two-component micro-dispensing of sea

Seite 2 - Contents

Product Configurator 10 313876F19 9640685 gallon tank, support, 5:11 pump, agita-tor, stainless steel20 9640695 gallon tank, support, 5:1 pump, agitat

Seite 3 - Related Manuals

Accessories313876F 11AccessoriesMixer Kits with ShroudMixer PacksPart Description964034 Mixer, Kit, 3/16 in. (4.8mm) x 24, 10 taper tip mixers with sh

Seite 4 - Warnings

Accessories 12 313876FO-Rings and SealsNeedlesPart Description24E247 Kit, O-ring, chemical resistant, PD4424E248 Kit, Seal, Spool, H.V., PD4424E249 Ki

Seite 5 - 313876F 5

Isocyanate Conditions313876F 13Isocyanate Conditions Material Self-ignition Moisture Sensitivity of IsocyanatesIsocyanates (ISO) are catalysts used i

Seite 6 - Product Configurator

Grounding 14 313876FGroundingThis product must be grounded. In the event of an elec-trical short circuit, grounding reduces the risk of electric shock

Seite 7

Component Identification313876F 15Component IdentificationTypical System Configurations FIG. 1Liquid Control Corp.NORTH CANTON, OH 44720 USA8400 PORT

Seite 8

Component Identification 16 313876FTypical Feed System Components FIG. 2DO NOT SERVICE WITHOUTREMOVING AIR PRESSURE ANDWEARING SAFETY GLASSES.WARNINGF

Seite 9

Component Identification313876F 17Typical Feed System Components (continued)FIG. 3R01284psi3022191526R01284psi30221915265 Gallon Tank with Diaphragm P

Seite 10

Component Identification 18 313876FMicrometer PD44 Metering ValveFIG. 4Key:A A Material InletB B Material InletC Grounding LugD Spool AssembliesE Mete

Seite 11 - Accessories

Component Identification313876F 19LRT PD44 Metering ValveFIG. 5BASide ViewFront ViewKey:A A Material InletB B Material InletC Grounding LugD Spool Ass

Seite 12 - O-Rings and Seals

2 313876FContentsRelated Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Models . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 13 - 313876F 13

Component Identification 20 313876FMotor Driven PD44 Metering ValveFIG. 6Side View Front ViewKey:A A Material InletB B Material InletC Grounding LugD

Seite 14 - Overview

Setup313876F 21SetupNOTE: See Typical Installation diagram.2. 1. Perform Setup procedure for feed system compo-nents. See feed system manuals. See Rel

Seite 15 - Component Identification

Setup 22 313876FTank Level Sensor Wiring SchematicValve Mounting DiagramAs desired, use the following diagram to mount the metering valve. TYPICAL LEV

Seite 16 - 16 313876F

Setup313876F 23Motor Mounting DiagramIf using a non-Graco motor with the Motor Driven PD44, use the following diagram to install the non-Graco motor o

Seite 17 - 313876F 17

Startup 24 313876FStartup1. Lubricate the metering rod ports in the oil cup retaining block and fill the spool valve ports with compatible lubricant.

Seite 18

Adjusting the Shot Size313876F 25Adjusting the Shot SizeMicrometer PD44 Only1. Rotate the shot size locking ring counterclockwise to loosen.2. Rotate

Seite 19 - LRT PD44 Metering Valve

Ratio Check 26 313876FRatio CheckPerform ratio check procedure at startup and after rebuild.1. Weigh six small cups and label as indicated. Record wei

Seite 20

Operation313876F 27OperationThe operation of the PD44 metering valve is controlled by an external source. If a PD44 Control Box was pur-chased, see th

Seite 21 - Typical Installation

Pressure Relief Procedure 28 313876FPressure Relief Procedure1. Retract the metering rods. See the PD44 Control Box manual. See Related Manuals on pag

Seite 22 - Valve Mounting Diagram

Troubleshooting313876F 29TroubleshootingSchematicsFor standard machines, the schematics will be included in the PD44 Parts manual. See Related Manu-al

Seite 23 - Custom Drive Mounting Diagram

Related Manuals313876F 3Related ManualsManuals are available at www.graco.comComponent manuals in U.S. English.Models* If a custom PD44 is ordered, it

Seite 24 - 24 313876F

Rebuild 30 313876FRebuild Wetted Section Disassembly1. Perform Pressure Relief Procedure, page 28.2. On Motor Driven PD44s, remove electrical power.3.

Seite 25 - Adjusting the Shot Size

Rebuild313876F 3111. Remove the four cap screws located at the top of the oil cup retaining block. 12. Remove the metering rods and oil cup retaining

Seite 26 - Ratio Check

Rebuild 32 313876FWetted Section Reassembly1. Install the pneumatic spool rod drive. Torque fasten-ers to 67-70 in-lb (7.5-7.9 N•m). 2. Repeat for oth

Seite 27 - Operation

Rebuild313876F 3311. Manually move connecting block up and down to insure rods are properly installed.12. Install the back plate and cap screws.13. In

Seite 28 - Maintenance

Rebuild 34 313876F6. Insert new o-ring into spool air cylinder end cap.7. Install proximity switch.8. Apply Krytox or compatible lubricant to cylinder

Seite 29 - Schematics

Rebuild313876F 356. For each pneumatic drive spool block, install new zap seals and o-rings onto o-ring retainer.7. Lubricate o-rings and bearing surf

Seite 30 - Rebuild

Rebuild 36 313876F12. Apply Krytox to spool rod then carefully install the spool rod into the spool sleeve (inside the metering block). Make sure not

Seite 31 - 313876F 31

Rebuild313876F 37Micrometer Drive Rebuild(Micrometer PD44 Only)1. Perform Wetted Section Disassembly, page 30.2. Remove the four cap screws located at

Seite 32 - Wetted Section Reassembly

Rebuild 38 313876F9. Install new posipak seal with the o-ring pointed towards the drive piston, then install washer and retaining ring.10. Apply Kryto

Seite 33 - Spool Valve Rebuild

Electrical Requirements313876F 39Electrical RequirementsElectrical requirements for pneumatically driven and stepper driven control boxes can be found

Seite 34 - Wetted Section Rebuild

Warnings 4 313876FWarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point

Seite 35 - 313876F 35

Electrical Requirements 40 313876FFIG. 14: Motor Driven PD44 Metering Valve Electrical RequirementsGROUNDSTUDPX-CSV(39.5")25"2" 2"

Seite 36 - "A" Side

Electrical Requirements313876F 41FIG. 15: LRT PD44 Metering Valve Electrical RequirementsFRONTPX-OSV(42.5")PX-CSV(39.5")YELLOWGREENBLUEREDRE

Seite 37 - Micrometer Drive Rebuild

Technical Data 42 313876FTechnical DataNOTE: See feed system manuals for dimensions, weights, and wetted parts lists for those components. Dimensions,

Seite 38 - 38 313876F

Technical Data313876F 43Motor SpecificationsIf a non-Graco motor is used with the Motor Driven PD44 Metering Valve, it must meet the following specifi

Seite 39 - Electrical Requirements

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Seite 40 - VIEW A-A

Warnings313876F 5ELECTRIC SHOCK HAZARDThis equipment must be grounded. Improper grounding, setup, or usage of the system can cause elec-tric shock.• T

Seite 41 - 313876F 41

Product Configurator 6 313876FProduct ConfiguratorThis system can be ordered with many different options as shown in the configurator below. The foll

Seite 42 - Technical Data

Product Configurator313876F 7Code E Part Low Volume Rod Material NOTE: See code FG for last two digits of part numberA 9641__ Hardened SteelB 9642__ S

Seite 43 - Motor Specifications

Product Configurator 8 313876FCode L Part Controls1 964035 Pneumatic, micrometer, wire harness only2 964036 Pneumatic, micrometer, HMI controls, low l

Seite 44 - Graco Information

Product Configurator313876F 919 9640685 gallon tank, support, 5:1 pump, agitator, stainless steel20 9640695 gallon tank, support, 5:1 pump, agitator,