308883S
EN
Instructions
50:1 Fire-Ball
®
300
Pump
For pumping non-corrosive and non-abrasive greases and lubricants only.For
professional use only.
Model No. 239877, Series D
pail length
Model No. 239887, Series D
120 lb drum length
Model No. 239888, Series D
400 lb drum length
8400 psi (58 MPa, 580 bar) Maximum Working Pressure
140 psi (0.97 MPa, 9.7 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
This product is designed to be used only in pumping
non-corrosive and non-abrasive lubricants and
greases. Any other use can cause unsafe operating
conditions and result in component rupture, fire, or
explosion, which can cause serious injury including
fluid injection.
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - 50:1 Fire-Ball

308883SENInstructions50:1 Fire-Ball® 300 PumpFor pumping non-corrosive and non-abrasive greases and lubricants only.For professional use only. Model N

Seite 2 - Warnings

Repair 10 308883SAir Motor and Throat SealsReassembly1. Clean all the parts carefully in a compatible solvent, and inspect for wear or damage. Use all

Seite 3 - Installation

Troubleshooting308883S 11Troubleshooting1. Follow Pressure Relief Procedure, page 5, before checking or repairing gun.2. Check all possible problems a

Seite 4 - Mounting

Parts 12 308883SParts29a29b281731*30*22132325272611151424*2338741a*1b*30*12*3869*10521**20**1964575318**47†60†6059†5652†56†62†61635866675416*

Seite 5 - Operation

Parts308883S 13Part No./Description Parts included in Kit 206728 (purchase separately).‡ Parts included in Kit 222559 (purchase separately).† Parts i

Seite 6 - Displacement Pump Service

Dimension Drawings 14 308883SDimension DrawingsMounting Hole LayoutOverall length:45.4 in. (1153 mm)Overall length:38.4 in. (975 mm)Overall length: 31

Seite 7 - 308883S 7

Technical Data308883S 15Technical Data .50:1 Fire-Ball® 300 PumpsUS MetricMaximum fluid working pressure 8400 psi 58 MPa, 580 barAir pressure operati

Seite 8 - Air Motor and Throat Service

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Seite 9 - 308883S 9

Warnings 2 308883SWarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point

Seite 10 - Air Motor and Throat Seals

Installation308883S 3Installation GroundingPump: Use a ground wire and clamp as shown in FIG. 1.Fluid hoses: Use only electrically conductive hoses.Ai

Seite 11 - Troubleshooting

Installation 4 308883SMounting1. Plan the mounting layout for easy operator access to the pump air controls, sufficient room to change drums and a sec

Seite 12 - 12 308883S

Operation308883S 5Operation Pressure Relief ProcedureFollow the Pressure Relief Procedure whenever you see this symbol.1. Close the pump air regulator

Seite 13 - Part No./Description

Repair 6 308883SRepairDisplacement Pump ServiceRefer to FIG. 3 for the following instructions.Be sure you have all necessary parts on hand before star

Seite 14 - Mounting Hole Layout

Repair308883S 7FIG. 3134Using nut (63), torque thepump cylinder (59) to the ex-tension tube (64) at 45–55 ft-lb(61–75 Nm).Torque the shovel rod (58)to

Seite 15 - Technical Data

Repair 8 308883SAir Motor and Throat ServiceRefer to FIG. 4 for the following instructions.Before starting, be sure to have all necessary parts on han

Seite 16 - Graco Standard Warranty

Repair308883S 9FIG. 4585764742112117386