Instructions/Parts List
CycleFlo II
309004C
ENG
Pneumatic Pump Controller
Controls pump speed for precise batching, metering, and dosing of fluids at high or low
pressures and flow rates.
Not for use in explosive atmospheres.
Part No. 195265
120 psi (0.8 MPa, 8 bar) Maximum Air Working
Pressure
Integrated Air Valves with Silenced Exhaust
Infinite Cycle Rate Adjustment Between 10 and
200 cpm
Standard 120 VAC Power
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Seitenansicht 0
1 2 3 4 5 6 ... 13 14

Inhaltsverzeichnis

Seite 1 - Pneumatic Pump Controller

Instructions/Parts List CycleFlo II 309004CENGPneumatic Pump Controller Controls pump speed for precise batching, metering, and dosing of fluids at hi

Seite 2 - Table of Contents

Parts Cycle rate adjustment relay Air Solenoid Valves Enclosure Part No. Description ----- Enclosure ----- Emblem (not shown – on front of unit)

Seite 3 - Equipment Misuse Hazard

Typical Installation Diagram *FlowSensors* Provided by others*Monitor / ControllerFlow Controller sends an on/offsignal (24VDC) to the isolation re

Seite 4

Typical Installation Diagram 9410ACycleFlo IIControllerCompressed Air InDiaphragm Pump(Husky 205 shown)*PH Controller,Flow ControllerTimer, etc. send

Seite 5 - Installation

Mounting Hole Layout All mounting tabsmay be placed ineither position7 3/8”(187 mm)5”(127 mm)7 3/8”(187 mm)5”(127 mm)13 309004

Seite 6 - Pneumatic Connections

Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from

Seite 7 - 7 309004

Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Gene

Seite 8 - Setup & Adjustment

Warning Symbol Caution Symbol This symbol alerts you to the possibility of serious injury or de

Seite 9 - Troubleshooting

Fire, Explosion, and Electric Shock Hazard Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and r

Seite 10

General Description The CycleFlo II is a pneumatic pump controller that allows precise control over the cycle rate of the pump and therefor the flow

Seite 11 - Typical Installation Diagram

Fig.1 - Electrical Diagrams Pneumatic Connections 6 309004 Cycle Rate Adjustment RelaySolenoid Valves120 Volt Signal

Seite 12 - Technical Data

The integrated air valves, have a common air inlet (1/4" NPT) port and two outlet ports A and B (1/4” Tube) toward the front of the unit. The exh

Seite 13 - Mounting Hole Layout

Setup & Adjustment Cycles Per Minute (CPM) Rate The pump cycle rate is adjustable to accommodate different pump sizes, varying product viscositi

Seite 14 - Graco Phone Number

Operation Priming the Pump Prime the pump by applying a 120 Volt signal to the controller to allow the temporary operation of the pump. This cycle r