OperationHusky™ 2200 Air-OperatedDiaphragm Pump3A2578BENPolypropylene and PVDF pumps for fluid transfer applications, including high viscosity material
InstallationGround The SystemThe equipment must be grounded to reduce therisk of static sparking. Static sparking can causefumes to ignite or explode.
InstallationAir Exhaust VentilationIf pumping toxic fluids, you must vent the exhaustaway from people, animals, food handling areas,and all sources of
InstallationFluid Supply Line1. Use grounded, flexible fluid hoses (E). SeeGround The System, page 10.2. If the inlet fluid pressure to the pump is moret
InstallationFlange ConnectionsThe fluid inlet and outlet ports are 2 in. (50 mm)raised face, ANSI/DIN PN 10 flanges. Connect 2 in.(50 mm) plastic pipe fl
OperationOperationPressure Relief ProcedureFollow the Pressure Relief Procedurewhenever you see this symbol.This equipment stays pressurized until pre
MaintenanceMaintenanceMaintenance ScheduleEstablish a preventive maintenance schedulebased on the pump’s service history. Scheduledmaintenanceis espec
Torque InstructionsTorque InstructionsIf fluid cover or manifold fasteners have beenloosened, it is important to torque them using thefollowing procedu
NotesNotes3A2578B17
DimensionsDimensionsEnd Flange Models, Polypropyleneand PVDFPolypropylene PVDFA 25.1 in. 63.8 cm 25.2 in. 64.0 cmB 28.7 in. 72.9 cm 28.8 in. 73.2 cmC3
DimensionsCenter FlangeModels, PolypropyleneOnlyPolypropyleneA 24.1 in. 61.2 cmB 27.2 in. 69.1 cmC30.3 in. 77.0 cmD 3.1 in. 7.9 cmE 12.8 in. 32.5 cmF
ContentsWarnings ... 3Ordering Information... 6Related
Performance ChartsPerformance ChartsBolt-through DiaphragmsFluid PressureApproximate Cycles per MinutePSI(MPa, bar)040(151)80(303)120(454)160(606)200(
Performa n ce ChartsOvermolded DiaphragmsFluid PressureApproximate Cycles per MinutePSI(MPa, bar)ABCD040(151)80(303)120(454)160(606)200(757)31 62 93 1
Technical DataTechnical DataHusky 2200 Diaphragm PumpUSMetricMaximum fluid working pressure125 psi 0.86 MPa, 8.6 barAir pressureoperating range20 to 12
Technical DataMaximum pump speedStandard diaphragms125 cycles per minuteOvermolded diaphragms155 cycles per minuteWeightPolypropylene 80 lb 36.3 kgPVD
Graco Standard Husky Pump WarrantyGraco warrants all equipment referenced in this document which is manufactured by Graco and bearing itsname to be fr
WarningsWarningsThe followingwarnings are for the setup, use, grounding, maintenance, and repair of this equipment. Theexclamation point symbol alerts
WarningsWARNINGEQUIPMENT MISUSE HAZARDMisuse can cause death or serious injury.• Do not operate the unit when fatigued or under the influence of drugs
WarningsWARNINGTOXIC FLUID OR FUMES HAZARDToxic fluids orfumes can cause serious injury or death if splashed in the eyes or on skin,inhaled, or swallow
Ordering InformationOrdering InformationTo Find Your Nearest Distributor1. Visit www.graco.com.2. Click on Where to Buy and use the DistributorLocator
Configuration Number MatrixConfigurationNumber MatrixCheck the identification plate (ID) for the Configuration Number of your pump. Use the following matr
InstallationInstallationGeneral InformationThe Typical Installation shown is only a guide forselecting and installing system components. Contactyour G
InstallationAccessories/Components Not Supplied System ComponentsA Air supply line JAir inlet port (not visible)BBleed-type master air valve (may bere