Operation - Maintenance
L-Head
For dispensing controlled ratio shots of resin and isocyanate.
3000 psi (20.6 MPa, 206 bar) Maximum Working Pressure
See page 2 for model information.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Operation - Maintenance

EN312753EOperation - Maintenance L-HeadFor dispensing controlled ratio shots of resin and isocyanate.3000 psi (20.6 MPa, 206 bar) Maximum Working Pres

Seite 2 - Contents

Maintenance 10 312753E Nozzle Grip Assembly Removal and Cleaning The nozzle grip assembly must be removed, disassem-bled and cleaned whenever disconne

Seite 3 - Warnings

Maintenance312753E 114. Using a clockwise twisting motion, pull the entire nozzle grip assembly out of the MixHead body. 5. If the injection nozzle w

Seite 4 - 4 312753E

Maintenance 12 312753E Cleanout Plunger ProximitySwitch Replacement The proximity switch on the cleanout plunger is a high-pressure switch that exten

Seite 5 - 312753E 5

Maintenance312753E 13Proximity Switch Replacement 1. Turn OFF the hydraulic fluid motor, bleed the hydraulic pressure to zero and allow the fluid to

Seite 6 - Component Identification

Maintenance 14 312753E Material Plunger ProximitySwitch Replacement Tools Required• M2.5 hex key for M4 flat head screws• Metric wrench (13mm)• Proxi

Seite 7

Maintenance312753E 15c. While holding the conduit (DB) stationary, tighten the adapter (DC) by hand until it con-tacts the jam nut (DD).d. Remove th

Seite 8 - Fluid Lines

Maintenance 16 312753E Key:DA Proximity SwitchDB ConduitDC AdapterDD 8 mm Jam NutDE Lock-washerDF Material PlungerDG Sensor Gauge MU1140DH Sensor Cap

Seite 9

Maintenance312753E 17Cleanout Plunger Stroke AdjustmentThe cleanout plunger stroke is properly set during fac-tory assembly so that the cleanout plun

Seite 10 - Nozzle Grip Assembly Removal

Maintenance 18 312753E 4. Place the steel rod between the two tie rods on top of the adjusting plug and carefully turn the adjusting plug clockwise to

Seite 11 - Installation

Maintenance312753E 19Pour Nozzle MaintenanceWith proper maintenance, the L-Head is capable of per-forming thousands of pours without the need for rem

Seite 12 - Switch Replacement

Models 2 312753E ContentsModels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Warnings . . . . . . . . . . . . . . . . .

Seite 13 - Proximity Switch Replacement

Maintenance 20 312753E Pour Nozzle Removal and InstallationTools Required• Torque wrench with M6 and M8 sockets• Fine-grade wire brushes on air tool1.

Seite 14 - Material Plunger Proximity

Troubleshooting312753E 21Troubleshooting Any individual working with the equipment must be knowledgeable in the necessary safety procedures.Unless o

Seite 15

Troubleshooting 22 312753E Hydraulic leak around Cleanout Plunger Proximity SwitchDamaged o-ring Replace o-ring See page 12Proximity Switch not tight-

Seite 16

Troubleshooting312753E 23

Seite 17 - Maintenance

Parts 24 312753E PartsModels 5/8, 6/10, 10/14123456789101112131415161817

Seite 18 - 18 312753E

Parts312753E 25Parts List * Part included in Nozzle Grip Assembly Seal Kit MK1490, which can be purchased separately.† Part included in Orifice Kits

Seite 19 - Pour Nozzle Maintenance

Parts 26 312753E Models 13/20 and 16/25 101102103104105106107108109110111112113114115116118117

Seite 20 - Replacement

Parts312753E 27Parts List * Parts included in Nozzle Grip Assembly Seal Kit MK1490, which can be purchased separately.† Part included in Orifice Kit

Seite 21 - Troubleshooting

Parts 28 312753E Orifice Kits Kit NumbersOrifice SelectionTo help choose the correct orifice for your application, use the following equation to find

Seite 22 - 22 312753E

Parts312753E 29Additional Tools and Accessories * Included in L-Head Tool Kit MK1184 for models 5/8, 6/10, and 10/14. Kit can be purchased separatel

Seite 23 - 312753E 23

Warnings312753E 3WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point

Seite 25 - Parts List

Technical Data312753E 31Technical DataProximity Switch Electrical Requirements . . . . Cleanout Piston: 50 mA @24VDCMaterial Piston: 60 mA @ 16 VDC

Seite 26 - Models 13/20 and 16/25

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Seite 27

Warnings 4 312753E EQUIPMENT MISUSE HAZARDMisuse can cause death or serious injury.• Do not operate the unit when fatigued or under the influence of d

Seite 28 - Orifice Kits

Isocyanate Hazard312753E 5Isocyanate HazardMaterial Self-ignitionMoisture Sensitivity of IsocyanatesIsocyanates (ISO) are catalysts used in two compo

Seite 29 - Accessories

Component Identification 6 312753E Component IdentificationKey:AEye BoltB Cleanout Plunger Open FittingC Resin Close FittingD Resin Open FittingE Resi

Seite 30 - 30 312753E

Installation312753E 7InstallationHydraulic & Chemical Hose InstallationBefore Disconnecting Hydraulic Fitting or Proximity Switch• Turn off the h

Seite 31 - Technical Data

Installation 8 312753E 5. Manually cycle the material plunger back and forth to check for proper operation. Check for hydraulic leaks and retighten fi

Seite 32 - Graco Information

Maintenance312753E 9Maintenance Maintenance Schedule All maintenance must be done with pressure relieved and the power switched off and locked out,