311593NENOperationE-Flo® 4-Ball Piston PumpsDurable, energy efficient piston pumps for high volume paint circulation applications. For professional us
Overview 10 311593N
Ground the System311593N 11Ground the SystemThe equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an es
Controls and Indicators 12 311593NControls and IndicatorsVariable Frequency Drive (VFD)Use a variable frequency drive (VFD) accessory to pro-vide moto
Setup311593N 13SetupFill gear reducer reservoir with oilOpen the fill cap (FC) and fill the gear reducer oil reser-voir with 2 quarts (1.9 liters) of
Operation 14 311593NOperationPressure Relief Procedure1. Set START/STOP switch (ST) to STOP. See FIG. 4.2. Push in SECURE DISABLE (SD) switch.3. Open
Operation311593N 15FIG. 7: Motor Speed and Flow ChartFlow Rategpm (lpm)30 (114)25 (95)20 (76)15 (57)10 (38)5 (19)Pump Cycles per Minute04 8 12 16 20 2
Maintenance 16 311593NMaintenancePreventive Maintenance ScheduleEstablish a preventive maintenance schedule based on the equipment’s repair history.Ch
Maintenance311593N 17Flushing• Flush before changing colors, before storing, and before repairing equipment.• Flush at the lowest pressure possible. C
Technical Data 18 311593NTechnical DataMaximum Working Pressure . . . . . . . . . . . . . . E-Flo 1500: 425 psi (2.93 MPa, 29.3 bar) E-Flo 2000: 460
Technical Data311593N 19Pressure and Flow Capability of E-Flo Family with 50 Hz Motor(continuous production use)Fluid Pressurepsi (MPa, bar)350 (2.41,
Related Manuals 2 311593NContentsRelated Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Models . . . . . . . . . . . . . . . . . .
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th
Models311593N 3ModelsE-Flo 4-Ball Piston PumpsCheck your pump’s identification plate (ID) for the 6-digit part number of your pump. Use the following
Models 4 311593N
Approvals311593N 5ApprovalsThe E-Flo Pump meets requirements of the following approval agencies.Refer to the individual components for other specific
Warnings 6 311593NWarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point
Warnings311593N 7ELECTRIC SHOCK HAZARD Improper grounding, setup, or usage of the system can cause electric shock.• Turn off and disconnect power at m
Overview 8 311593NOverviewAn electric motor (B) provides input to a 75:1 gear reducer (GR), which drives two fluid pumps (FP). See FIG. 1. The stroke
Overview311593N 9Key:AE-Flo Electric Circulation PumpB* Explosion-Proof Electric MotorC* Local Control BoxD* Variable Frequency Drive (VFD)E** System