Instructions–Parts List308797PALUMINUMHuskyt 716 Air–operatedDiaphragm PumpsUsed to evacuate and transfer fluids.100 psi (0.7 MPa, 7 bar) Maximum Flui
10 308797OperationPressure Relief ProcedureWARNINGPRESSURIZED EQUIPMENT HAZARDThe equipment stays pressurized until pressure ismanually relieved. To r
11308797MaintenanceLubricationThe air valve is lubricated at the factory to operatewithout additional lubrication. If you want to provideadditional l
12 308797TroubleshootingRead Pressure Relief Procedure on page 10, and relieve the pressure before you check or servicethe equipment. Check all possi
13308797ServiceAir ValveNOTE: Air Valve Repair Kit 241657 is available. Parts included in the kit are marked with a dagger () in Fig. 5 andin the Pa
14 308797ServiceBall Check ValvesNOTE: Fluid Section Repair Kit D05977 is available.See page 21 to order the correct kit for your pump.Parts included
15308797ServiceFig. 61392011012021391392012021393013011051051061061071021021Torque to 80 to 90 in-lb (9 to 10 Nm). SeeTorque Sequence, page
16 308797ServiceDiaphragmsNOTE: Fluid Section Repair Kit D05977 is available. Parts included in the kit are marked with a double dagger ()in Fig. 7
17308797ServiceDiaphragmsFig. 711 Included in Fluid Section Repair Kit D0597712Torque to 35 to 45 in-lb (4.0 to 5.1 N-m).Apply grease.The words “AIR
11413101613920113441511091011021022021393011081121124014021031171051051061061076133115Grounding Detail1211221239872 Included in Air Va
19308797241407 and 241408 Parts ListFluid Section Parts List Ref.No.PartNo.Description Qty101 185622 COVER, fluid; aluminum 2102 185624 MANIFOLD; alum
2 308797Table of ContentsWarnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4. . . . . . . . . . . . .
20 308797Torque SequenceAlways follow torque sequence when instructed to torque fasteners.1. Left/Right Fluid CoversTorque bolts to 80–90 in–lb (9–10
21308797Technical DataMaximum fluid working pressure 100 psi (0.7 MPa, 7 bar). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 308797Husky 716 Dimensions1.38 in.(35.1 mm)FRONT VIEWSIDE VIEW1/4 npt(f)Air Inlet6.04 in.(153.4 mm)7.37 in.(187.2 mm)PUMP MOUNTING HOLE PATTERNFour
23308797Performance Charts0204060801000246810121416(7.6) (15.2) (22.7) (30.3) (37.9) (45.4) (53.0) (60.6)Fluid Outlet PressureTest Conditions: Pump t
24 308797Performance Charts0510152025300246810121416(7.6) (15.2) (22.7) (30.3) (37.9) (45.4) (53.0) (60.6)Air ConsumptionTest Conditions: Pump tested
25308797Notes
26 308797Graco WarrantiesGraco Standard Husky Pump WarrantyGraco warrants all equipment manufactured by Graco and bearing its name to be free from def
3308797WARNINGTOXIC FLUID HAZARDHazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,inhaled, or sw
4 308797InstallationGeneral Information The Typical Installations in Fig. 2 are only guidesfor selecting and installing system components.Contact you
5308797InstallationAir LineWARNINGA bleed-type master air valve (B) is required in yoursystem to relieve air trapped between this valveand the pump. S
6 308797InstallationFluid Pressure Relief ValveCAUTIONSome systems may require installation of a pressurerelief valve at the pump outlet to prevent ov
7308797InstallationKEYA PumpC Electrically conductive air supply lineD Air line quick disconnectH Fluid drain valve (required)K Electrically conductiv
8 308797InstallationGroundingWARNINGFIRE AND EXPLOSION HAZARDThis pump must be grounded. Beforeoperating the pump, ground the systemas explained below
9308797InstallationChanging the Orientation of the Fluid Inletand Outlet PortsFig. 4. You can change the orientation of the fluid inletand outlet port
Kommentare zu diesen Handbüchern