Instructions
Hydraulic Fluid
Controls
308395D
EN
Regulates hydraulic pressure and flow when used with Graco’s Dyna-Star
™
and
Power-Star
™
hydraulic-powered lubricant pumps. For professional use only.
Model 236864
Used with Dyna-Star
™
1500 psi (10.5 MPa, 105 bar) Maximum Working Pres-
sure
3 gpm (11 liters/min) Maximum Flow Rate
Model 236865
Used with Power-Star
™
1500 psi (10.5 MPa, 150 bar) Maximum Working Pres-
sure
12 gpm (45 liters/min) Maximum Flow Rate
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
Hydraulic fluid controls are designed to control
hydraulic fluids only in a hydraulic power system. Any
other fluids can cause unsafe operating conditions
and results in component rupture, fire, or explosion
which could result in serious injury, including fluid
injection.
Model 236865
Model 236864
Seitenansicht 0
1 2 3 4 5 6 ... 13 14

Inhaltsverzeichnis

Seite 1 - Controls

InstructionsHydraulic Fluid Controls308395DENRegulates hydraulic pressure and flow when used with Graco’s Dyna-Star™ and Power-Star™ hydraulic-powered

Seite 2 - Warnings

Parts 10 308395DPartsModel 236864 Hydraulic Fluid Control113a113b111105104108109106102112107113Includes items113a & 113b1031110110103Ref. Part Des

Seite 3 - 308395D 3

Parts308395D 11Model 236865 Hydraulic Fluid Control113b107102105106103112113109104113a108Includes items113a & 113b111111110110Ref. Part Descriptio

Seite 4 - Installation

Technical Data 12 308395DTechnical DataDimensionsHydraulic Fluid Controls: Dyna-Star™US MetricMaximum fluid working pressure 1500 psi 10.5 MPa, 105 b

Seite 6 - Hydraulic Components

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Seite 7 - Operation

Warnings 2 308395DWarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point

Seite 8 - Flow Control Repair

Warnings308395D 3EQUIPMENT MISUSE HAZARDMisuse can cause death or serious injury.• Do not operate the unit when fatigued or under the influence of dru

Seite 9 - Troubleshooting

Installation 4 308395DInstallation GroundingPump: use ground wire and clamp (supplied). Loosen grounding lug locknut (W) and washer (V). Insert one en

Seite 10 - 10 308395D

Installation308395D 5Typical InstallationKey:A Hydraulic Control, 236864B Hydraulic Control, 236865C Hydraulic Return LineD Hydraulic Outlet, 3/4 npsm

Seite 11 - 308395D 11

Installation 6 308395DInstallation Notes• Blow out all hydraulic lines with air, flush thoroughly with solvent, and then blow out the air again before

Seite 12 - Dimensions

Operation308395D 7OperationPressure Relief ProcedureFollow the Pressure Relief Procedure whenever you see this symbol.1. Close the supply line shutoff

Seite 13 - 308395D 13

Repair 8 308395DShutdown Always shut off the supply line shutoff valve (E) first, and then the return line shutoff valve (G). This is to prevent over

Seite 14 - Graco Information

Troubleshooting308395D 9TroubleshootingProblem Cause SolutionNo pressure on gauge, or low pres-sure on gaugeHydraulic power supply malfunction or mis-